--  Avocent PM MIB
--  Copyright 2010 Avocent Corporation
--  Revision: 2.0.1
--  Last Modified: Nov 24, 2010
--------------------------------------------------------------------------------

PM-MIB DEFINITIONS ::= BEGIN

IMPORTS
  enterprises, OBJECT-TYPE, MODULE-IDENTITY, Integer32
      FROM SNMPv2-SMI
  DisplayString
      FROM SNMPv2-TC
  InterfaceIndex, InterfaceIndexOrZero
        FROM IF-MIB;

--------------------------------------------------------------------------------
-- Object Groupings
--------------------------------------------------------------------------------

--@ Note: every product type should be uniquely identified underneath the
--@ Products object group. Each product should report its unique Products
--@ OBJECT IDENTIFIER in mib-2.system.sysObjectID. Please see the file
--@ "_Avocent Enterprise Object Identifier Assignment.txt" for a list of the
--@ IDs that have been assigned.

-- enterprises  .1.3.6.1.4.1

-- avocent         OBJECT IDENTIFIER ::= { enterprises 10418 }

pm    MODULE-IDENTITY
        LAST-UPDATED    "201011240000Z"
        ORGANIZATION    "Avocent Corporation"
        CONTACT-INFO    "postal : Avocent Corporation
                                  47281 Bayside Parkway
                                  Fremont, CA 94538, USA
                         e-mail : Technical Support
                                  techsupport@avocent.com"
        DESCRIPTION        
        "This module defines the Avocent MIB extensions to 
         PM-PDU products."

        REVISION        "201011240000Z"
        DESCRIPTION     "Adding Power Management OIDs.
                         Fixed SYNTAX of some OIDs.
                         Updating OIDs DESCRIPTION to include not applicable values."  

        REVISION        "201009240000Z"
        DESCRIPTION     "Syntax fixed to pass validation level 3."

        REVISION        "201004140000Z"
        DESCRIPTION     "Obsoleting fixed index OIDs from PDU table.
                         Added measurent type and alarm in PDU table.
                         Added missing power factor reset in outlet table.
                         Added sensor type and digital status in sensors table."

        REVISION        "200905210000Z"
        DESCRIPTION     "New tables for power measurements"
::= { enterprises 10418 17 }

pmProducts     OBJECT IDENTIFIER ::= { pm 1 }
pmManagement   OBJECT IDENTIFIER ::= { pm 2 }
--
pm1024         OBJECT IDENTIFIER ::= { pmProducts 1 }    -- 10418.17.1.1
pm2003         OBJECT IDENTIFIER ::= { pmProducts 2 }    -- 10418.17.1.2
pm2006         OBJECT IDENTIFIER ::= { pmProducts 3 }    -- 10418.17.1.3
pm2024         OBJECT IDENTIFIER ::= { pmProducts 4 }
pm3003         OBJECT IDENTIFIER ::= { pmProducts 5 }
pm3006         OBJECT IDENTIFIER ::= { pmProducts 6 }
pm3024         OBJECT IDENTIFIER ::= { pmProducts 7 }
pm1010         OBJECT IDENTIFIER ::= { pmProducts 8 }
pm2010         OBJECT IDENTIFIER ::= { pmProducts 9 }
pm3010         OBJECT IDENTIFIER ::= { pmProducts 10 }
pm1020         OBJECT IDENTIFIER ::= { pmProducts 11 }
pm2020         OBJECT IDENTIFIER ::= { pmProducts 12 }
pm3020         OBJECT IDENTIFIER ::= { pmProducts 13 }

pmAppliance    OBJECT IDENTIFIER ::= { pmManagement 1  }  -- 10418.17.2.1
pmSessions     OBJECT IDENTIFIER ::= { pmManagement 2  }  -- 10418.17.2.2
pmPowerMgmt    OBJECT IDENTIFIER ::= { pmManagement 5  }  -- 10418.17.2.5

--
-- Note that traps are defined in a separate trap MIB 
--
pmTrapObject   OBJECT IDENTIFIER ::= { pmManagement 6 }  -- 10418.17.2.6


--
-- pmAppliance 
-- OBJECT IDENTIFIER ::= { pmManagement 1  }  10418.17.2.1
--
pmHostName OBJECT-TYPE
        SYNTAX             DisplayString ( SIZE (0..32) )
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "The appliance name"
::= { pmAppliance 1 }

pmProductModel OBJECT-TYPE
        SYNTAX             DisplayString ( SIZE (0..50) )
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "The appliance product model"
::= { pmAppliance 2 }

pmPartNumber OBJECT-TYPE
        SYNTAX             DisplayString ( SIZE (0..32) )
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "The part number of this appliance as shown on the label
         attached or imprinted on the appliance."
::= { pmAppliance 3 }

pmSerialNumber OBJECT-TYPE
        SYNTAX             DisplayString ( SIZE (0..32) )
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "The serial number of this appliance as shown on the label
         attached or imprinted on the appliance."
::= { pmAppliance 4 }

pmEIDNumber OBJECT-TYPE
        SYNTAX             DisplayString ( SIZE (0..32) )
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "The electronic ID number (EID) of this appliance as shown on the label
         attached or imprinted on the appliance."
::= { pmAppliance 5 }

pmBootcodeVersion OBJECT-TYPE
        SYNTAX             DisplayString ( SIZE (0..32) )
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION 
        "The version of the bootcode of this appliance."
::= { pmAppliance 6 }

pmFirmwareVersion OBJECT-TYPE
        SYNTAX             DisplayString ( SIZE (0..32) )
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION 
        "The version of the firmware of this appliance."
::= { pmAppliance 7 }

pmReboot OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reboot(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION 
        "A set value of reboot(2) will reboot the appliance.
         noAction(1) = always returned in a GET. Does nothing if SET.        
         reboot(2)   = when SET the appliance immediately reboots."
::= { pmAppliance 9 }

--
-- pmSessions      
-- OBJECT IDENTIFIER ::= { pmManagement 2  }   10418.17.2.2
--
pmActiveSessionsNumberOfSession OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of active sessions."
::= { pmSessions 1 }

pmActiveSessionsTable OBJECT-TYPE
        SYNTAX             SEQUENCE OF PmActiveSessionsTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION
        "This table contains the list of active sessions."
::= { pmSessions 2 }
 
pmActiveSessionsTableEntry OBJECT-TYPE
        SYNTAX             PmActiveSessionsTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION                
        "each entry has the information about the active session"
        INDEX        { pmActiveSessionsTableIndex }
::= { pmActiveSessionsTable 1 }

PmActiveSessionsTableEntry ::= SEQUENCE  {
        pmActiveSessionsTableIndex        InterfaceIndexOrZero,     
        pmActiveSessionsTableUser         DisplayString, -- user name
        pmActiveSessionsTableGroup        DisplayString, -- group name
        pmActiveSessionsTableType         DisplayString, -- RO/RW-ssh,telnet or web 
        pmActiveSessionsTableConnection   DisplayString, -- type + target name
        pmActiveSessionsTableSessionTime  DisplayString, -- time of session
        pmActiveSessionsTableFrom         DisplayString, -- source of the session
        pmActiveSessionsTableKill         INTEGER
}

pmActiveSessionsTableIndex OBJECT-TYPE
        SYNTAX             InterfaceIndexOrZero
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "A unique index representing an entry in this table."
::= { pmActiveSessionsTableEntry 1 }

pmActiveSessionsTableUser OBJECT-TYPE
        SYNTAX             DisplayString ( SIZE (0..32) )
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION 
        "The name of the user that opens this session."
::= { pmActiveSessionsTableEntry 2 }

pmActiveSessionsTableGroup OBJECT-TYPE
        SYNTAX             DisplayString ( SIZE (0..32) )
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION 
        "The name of the group that the user belongs to."
::= { pmActiveSessionsTableEntry 3 }

pmActiveSessionsTableType OBJECT-TYPE
        SYNTAX             DisplayString ( SIZE (0..32) )
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION 
        "The session type."
::= { pmActiveSessionsTableEntry 4 }

pmActiveSessionsTableConnection OBJECT-TYPE
        SYNTAX             DisplayString ( SIZE (0..32) )
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION 
        "Connection type."
::= { pmActiveSessionsTableEntry 5 }

pmActiveSessionsTableSessionTime OBJECT-TYPE
        SYNTAX             DisplayString ( SIZE (0..32) )
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION 
        "Time of the session"
::= { pmActiveSessionsTableEntry 6 }

pmActiveSessionsTableFrom OBJECT-TYPE
        SYNTAX             DisplayString ( SIZE (0..32) )
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION 
        "The source IP address of the session."
::= { pmActiveSessionsTableEntry 7 }

pmActiveSessionsTableKill OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                killSession(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION 
        "A set value of killSession(2) will kill the session.
         noAction(1)   = always returned in a GET. Does nothing if SET.
         killSession(2)= when SET the appliance immediately kills the session."
::= { pmActiveSessionsTableEntry 8 }


--
-- pmPowerMgmt     
-- OBJECT IDENTIFIER ::= { pmManagement 5  }   10418.17.2.5
--
pmPowerMgmtNumSerialPorts OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION   
        "The number of Serial Ports that has PDU connected on the appliance."
::= { pmPowerMgmt 1 }

pmPowerMgmtSerialTable OBJECT-TYPE
        SYNTAX             SEQUENCE OF PmPowerMgmtSerialTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION
        "Information about each serial port thas has PDU connect."
::= { pmPowerMgmt 2 }

pmPowerMgmtSerialTableEntry OBJECT-TYPE
        SYNTAX             PmPowerMgmtSerialTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION     
        "Information about each serial port thas has PDU connect."
        INDEX           { pmPowerMgmtSerialTableIndex }
::= { pmPowerMgmtSerialTable 1 }

PmPowerMgmtSerialTableEntry ::= SEQUENCE  {
        pmPowerMgmtSerialTableIndex          InterfaceIndex,   
        pmPowerMgmtSerialTablePortNumber     Integer32,
        pmPowerMgmtSerialTableDeviceName     DisplayString,     
        pmPowerMgmtSerialTableNumberPDUs     Integer32,
        pmPowerMgmtSerialTableBuzzer         Integer32,
        pmPowerMgmtSerialTableSyslog         Integer32,
        pmPowerMgmtSerialTableOverCurrent    Integer32,
        pmPowerMgmtSerialTableCycleInterval  Integer32,
        pmPowerMgmtSerialTablePollRate       Integer32,
        pmPowerMgmtSerialTablePassWord       DisplayString,
        pmPowerMgmtSerialTableSave           INTEGER,
        pmPowerMgmtSerialTableRestore        INTEGER
}

pmPowerMgmtSerialTableIndex OBJECT-TYPE
        SYNTAX             InterfaceIndex   
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "The index of the register."
::= { pmPowerMgmtSerialTableEntry 1 }

pmPowerMgmtSerialTablePortNumber OBJECT-TYPE
        SYNTAX             Integer32        
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "The number of the serial port when the PDU is connected."
::= { pmPowerMgmtSerialTableEntry 2 }

pmPowerMgmtSerialTableDeviceName OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "The device name of this serial port."
::= { pmPowerMgmtSerialTableEntry 3 }

pmPowerMgmtSerialTableNumberPDUs OBJECT-TYPE
        SYNTAX             Integer32     
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Total number of units connected in this serial port."
::= { pmPowerMgmtSerialTableEntry 4 }

pmPowerMgmtSerialTableBuzzer OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "set/get buzzer(s) on or off for the chain.
         Returns 0 if not supported."
::= { pmPowerMgmtSerialTableEntry 10 }

pmPowerMgmtSerialTableSyslog OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "set/get syslog on or off for the chain.
         Returns 0 if not supported."
::= { pmPowerMgmtSerialTableEntry 11 }

pmPowerMgmtSerialTableOverCurrent OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "set/get over current proctection on or off for the chain.
         Returns 0 if not supported."
::= { pmPowerMgmtSerialTableEntry 12 }

pmPowerMgmtSerialTableCycleInterval OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "set/get cycle interval for the chain in whole seconds.
         Returns 0 if not supported."
::= { pmPowerMgmtSerialTableEntry 13 }

pmPowerMgmtSerialTablePollRate OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "set/get the poll rate for the chain in whole seconds.
         Returns 0 if not supported."
::= { pmPowerMgmtSerialTableEntry 14 }

pmPowerMgmtSerialTablePassWord OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "set the global password for admin user"
::= { pmPowerMgmtSerialTableEntry 15 }

pmPowerMgmtSerialTableSave OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                save(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         save(2)  = when SET the save command is sent to PDU."
::= { pmPowerMgmtSerialTableEntry 20 }

pmPowerMgmtSerialTableRestore OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                restore(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         restore(2)  = when SET the restore command is sent to PDU."
::= { pmPowerMgmtSerialTableEntry 21 }

pmPowerMgmtPDUTable OBJECT-TYPE
        SYNTAX             SEQUENCE OF PmPowerMgmtPDUTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION
        "This table contains the list of detected PDUs."
::= { pmPowerMgmt 3 }
 
pmPowerMgmtPDUTableEntry OBJECT-TYPE
        SYNTAX             PmPowerMgmtPDUTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION                
        "each entry has the information about the PDU."
        INDEX              { pmPowerMgmtPDUTablePortNumber, pmPowerMgmtPDUTablePduIndex }
::= { pmPowerMgmtPDUTable 1 }

PmPowerMgmtPDUTableEntry ::= SEQUENCE  {
        pmPowerMgmtPDUTablePortNumber        InterfaceIndex,   -- number of serial port
        pmPowerMgmtPDUTablePduIndex          InterfaceIndexOrZero,     
        pmPowerMgmtPDUTablePduId             DisplayString,    -- PDU identification
        pmPowerMgmtPDUTablePortName          DisplayString,    -- Serial Port Name
        pmPowerMgmtPDUTableModel             DisplayString,    -- PDU model
        pmPowerMgmtPDUTableVendor            DisplayString,    -- Vendor
        pmPowerMgmtPDUTableFirmwareVersion   DisplayString,    -- Firmware Version
        pmPowerMgmtPDUTableNumberOfOutlets   Integer32, 
        pmPowerMgmtPDUTableCurrentNOS        Integer32,        -- OBSOLETED number of current sensors
        pmPowerMgmtPDUTableCurrent1Value     Integer32,        -- OBSOLETED actual value for current of the sensor 1
        pmPowerMgmtPDUTableCurrent1Max       Integer32,        -- OBSOLETED max value for current of the sensor 1
        pmPowerMgmtPDUTableCurrent2Value     Integer32,        -- OBSOLETED actual value for current of the sensor 2
        pmPowerMgmtPDUTableCurrent2Max       Integer32,        -- OBSOLETED max value for current of the sensor 2
        pmPowerMgmtPDUTableCurrent3Value     Integer32,        -- OBSOLETED actual value for current of the sensor 3
        pmPowerMgmtPDUTableCurrent3Max       Integer32,        -- OBSOLETED max value for current of the sensor 3
        pmPowerMgmtPDUTableTemperatureNOS    Integer32,        -- OBSOLETED number of temperature  sensors
        pmPowerMgmtPDUTableTemperature1Value Integer32,        -- OBSOLETED actual value for Temperature 1
        pmPowerMgmtPDUTableTemperature1Max   Integer32,        -- OBSOLETED max value for Temperature 1
        pmPowerMgmtPDUTableTemperature2Value Integer32,        -- OBSOLETED actual value for Temperaturet 2
        pmPowerMgmtPDUTableTemperature2Max   Integer32,        -- OBSOLETED max value for Temperature 2
        pmPowerMgmtPDUTableTemperature3Value Integer32,        -- OBSOLETED actual value for Temperature 3
        pmPowerMgmtPDUTableTemperature3Max   Integer32,        -- OBSOLETED max value for Temperature 3
        pmPowerMgmtPDUTableHumidityNOS       Integer32,        -- OBSOLETED humidity number of humidity sensors
        pmPowerMgmtPDUTableHumidity1Value    Integer32,        -- OBSOLETED actual value for Humidity of the sensor 1
        pmPowerMgmtPDUTableHumidity1Max      Integer32,        -- OBSOLETED max value for Humidityof the sensor 1
        pmPowerMgmtPDUTableHumidity2Value    Integer32,        -- OBSOLETED actual value for Humidity of the sensor 2
        pmPowerMgmtPDUTableHumidity2Max      Integer32,        -- OBSOLETED max value for Humidity of the sensor 2
        pmPowerMgmtPDUTableHumidity3Value    Integer32,        -- OBSOLETED actual value for Humidity of the sensor 3
        pmPowerMgmtPDUTableHumidity3Max      Integer32,        -- OBSOLETED max value for Humidity of the sensor 3
        pmPowerMgmtPDUTableVoltageNOS        Integer32,        -- OBSOLETED number of voltage sensor
        pmPowerMgmtPDUTableVoltage1Value     Integer32,        -- OBSOLETED actual value for Voltage of the sensor 1
        pmPowerMgmtPDUTableVoltage1Max       Integer32,        -- OBSOLETED max value for Voltage of the sensor 1
        pmPowerMgmtPDUTableVoltage2Value     Integer32,        -- OBSOLETED actual value for Voltage of the sensor 2
        pmPowerMgmtPDUTableVoltage2Max       Integer32,        -- OBSOLETED max value for Voltaget of the sensor 2
        pmPowerMgmtPDUTableVoltage3Value     Integer32,        -- OBSOLETED actual value for Voltage of the sensor 3
        pmPowerMgmtPDUTableVoltage3Max       Integer32,        -- OBSOLETED max value for Voltage of the sensor 3
        pmPowerMgmtPDUTableNumberOfPhases    Integer32,        -- number of phases (0 if single phase)
        pmPowerMgmtPDUTableNumberOfBanks     Integer32,        -- number of banks
        pmPowerMgmtPDUTableNumberOfSensors   Integer32,        -- number of sensors
        pmPowerMgmtPDUTableFactoryDefault    INTEGER,          -- set PDU to factory default settings
        pmPowerMgmtPDUTableColdStartDelay    Integer32,        -- get/set PDUs cold start delay
        pmPowerMgmtPDUTableReboot            INTEGER,          -- reboot the PDU
        pmPowerMgmtPDUTableMaxCurrent        Integer32,        -- max value allowed for current
        pmPowerMgmtPDUTableAlarm             INTEGER,          -- PDU alarm status
        pmPowerMgmtPDUTableCurrentValue      Integer32,        -- actual value for current of the sensor
        pmPowerMgmtPDUTableCurrentMax        Integer32,        -- max value for current
        pmPowerMgmtPDUTableCurrentMin        Integer32,        -- min value for current
        pmPowerMgmtPDUTableCurrentAvg        Integer32,        -- average value for current
        pmPowerMgmtPDUTableCurrentReset      INTEGER,          -- reset the current stats
        pmPowerMgmtPDUTablePowerValue        Integer32,        -- actual value for power
        pmPowerMgmtPDUTablePowerMax          Integer32,        -- max value for power
        pmPowerMgmtPDUTablePowerMin          Integer32,        -- min value for power
        pmPowerMgmtPDUTablePowerAvg          Integer32,        -- average value for power
        pmPowerMgmtPDUTablePowerReset        INTEGER,          -- reset the power stats
        pmPowerMgmtPDUTablePowerType         INTEGER,          -- type of power measurement 
        pmPowerMgmtPDUTableVoltageValue      Integer32,        -- actual value for voltage
        pmPowerMgmtPDUTableVoltageMax        Integer32,        -- max value for voltage
        pmPowerMgmtPDUTableVoltageMin        Integer32,        -- min value for voltage
        pmPowerMgmtPDUTableVoltageAvg        Integer32,        -- average value for voltage
        pmPowerMgmtPDUTableVoltageReset      INTEGER,          -- reset the voltage stats
        pmPowerMgmtPDUTableVoltageType       INTEGER,          -- type of voltage measurement
        pmPowerMgmtPDUTablePowerFactorValue  Integer32,        -- actual value for powerfactor
        pmPowerMgmtPDUTablePowerFactorMax    Integer32,        -- max value for powerfactor
        pmPowerMgmtPDUTablePowerFactorMin    Integer32,        -- min value for powerfactor
        pmPowerMgmtPDUTablePowerFactorAvg    Integer32,        -- average value for powerfactor
        pmPowerMgmtPDUTablePowerFactorReset  INTEGER,          -- reset the powerfactor stats
        pmPowerMgmtPDUTablePowerFactorType   INTEGER,          -- type of power factor measurement
        pmPowerMgmtPDUTablePowerControl      INTEGER,          -- manage the outlets in this PDU
        pmPowerMgmtPDUTableResetOCP          INTEGER,          -- reset the ocp (pdu wide)
        pmPowerMgmtPDUTableCurrentHighCritical    Integer32,   -- get/set current high critical threshold
        pmPowerMgmtPDUTableCurrentHighWarning     Integer32,   -- get/set current high warning threshold
        pmPowerMgmtPDUTableCurrentLowWarning      Integer32,   -- get/set current low warning threshold
        pmPowerMgmtPDUTableCurrentLowCritical     Integer32,   -- get/set current low critical threshold
        pmPowerMgmtPDUTableEnergyValue       Integer32,        -- Energy value
        pmPowerMgmtPDUTableEnergyStartTime   DisplayString,    -- time at which energy calculation commenced
        pmPowerMgmtPDUTableEnergyReset       INTEGER           -- reset energy calculation and start time to now
}

pmPowerMgmtPDUTablePortNumber OBJECT-TYPE
        SYNTAX             InterfaceIndex
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of serial port when the PDU is connected."
::= { pmPowerMgmtPDUTableEntry 1 }

pmPowerMgmtPDUTablePduIndex OBJECT-TYPE
        SYNTAX             InterfaceIndexOrZero
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "A PDU position in the chain."
::= { pmPowerMgmtPDUTableEntry 2 }

pmPowerMgmtPDUTablePduId  OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "PDU identification."
::= { pmPowerMgmtPDUTableEntry 3 }

pmPowerMgmtPDUTablePortName OBJECT-TYPE
        SYNTAX             DisplayString

        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Name of serial port when the PDU is connected."
::= { pmPowerMgmtPDUTableEntry 4 }

pmPowerMgmtPDUTableModel  OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Model of the PDU.
         Returns N/A if not applicable."
::= { pmPowerMgmtPDUTableEntry 5 }

pmPowerMgmtPDUTableVendor   OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Vendor of the PDU.
         Returns N/A if not applicable."
::= { pmPowerMgmtPDUTableEntry 6 }

pmPowerMgmtPDUTableFirmwareVersion        OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Version of the PDU firmware.
         Returns N/A if not applicable."
::= { pmPowerMgmtPDUTableEntry 7 }

pmPowerMgmtPDUTableNumberOfOutlets OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of outlets of the PDU."
::= { pmPowerMgmtPDUTableEntry 8 }

pmPowerMgmtPDUTableCurrentNOS OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Number of current sensors in the PDU."
::= { pmPowerMgmtPDUTableEntry 9 }

pmPowerMgmtPDUTableCurrent1Value OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Current of the sensor 1 in this PDU unit in AMP.
         The value of this object is the actual current in 
         AMP * 10. You need to translate the readed value
         (Ex. : value is 5, the current is 0.5 AMP.).
         This OID is obsoleted. The value can be retrieved
         from pmPowerMgmtPDUTableCurrentValue, 
         pmPowerMgmtPhasesTableCurrentValue, or 
         pmPowerMgmtOutletsTableCurrentValue"
::= { pmPowerMgmtPDUTableEntry 10 }

pmPowerMgmtPDUTableCurrent1Max OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             obsolete
        DESCRIPTION
        "Maximum current of the sensor 1 in this PDU unit in AMP.
         When the PDU does not have support for maximum value,
         the value will be 0.
         The value of this object is the actual current in 
         AMP * 10. You need to translate the readed value
         (Ex. : value is 5, the current is 0.5 AMP.)
         Clear this value, set it with Zero value. 
         This OID is obsoleted. The value can be retrieved
         from pmPowerMgmtPDUTableCurrentMax, 
         pmPowerMgmtPhasesTableCurrentMax, or 
         pmPowerMgmtOutletsTableCurrentMax"
::= { pmPowerMgmtPDUTableEntry 11 }

pmPowerMgmtPDUTableCurrent2Value OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Current of the sensor 2 in this PDU unit in AMP.
         The value of this object is the actual current in 
         AMP * 10. You need to translate the readed value
         (Ex. : value is 5, the current is 0.5 AMP.). 
         This OID is obsoleted. The value can be retrieved
         from pmPowerMgmtPDUTableCurrentValue, 
         pmPowerMgmtPhasesTableCurrentValue, or 
         pmPowerMgmtOutletsTableCurrentValue"
::= { pmPowerMgmtPDUTableEntry 12 }

pmPowerMgmtPDUTableCurrent2Max OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             obsolete
        DESCRIPTION
        "Maximum current of the sensor 2 in this PDU unit in AMP.
          When the PDU does not have support for maximum value,
         the value will be 0.
         The value of this object is the actual current in 
         AMP * 10. You need to translate the readed value
         (Ex. : value is 5, the current is 0.5 AMP.)
         Clear this value, set it with Zero value. 
         This OID is obsoleted. The value can be retrieved
         from pmPowerMgmtPDUTableCurrentMax, 
         pmPowerMgmtPhasesTableCurrentMax, or 
         pmPowerMgmtOutletsTableCurrentMax"
::= { pmPowerMgmtPDUTableEntry 13}

pmPowerMgmtPDUTableCurrent3Value OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Current of the sensor 3 in this PDU unit in AMP.
         The value of this object is the actual current in 
         AMP * 10. You need to translate the readed value
        (Ex. : value is 5, the current is 0.5 AMP.) 
         This OID is obsoleted. The value can be retrieved
         from pmPowerMgmtPDUTableCurrentValue, 
         pmPowerMgmtPhasesTableCurrentValue, or 
         pmPowerMgmtOutletsTableCurrentValue"
::= { pmPowerMgmtPDUTableEntry 14 }

pmPowerMgmtPDUTableCurrent3Max OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             obsolete
        DESCRIPTION
         "Maximum current of the sensor 3 in this PDU unit in AMP.
         When the PDU does not have support for maximum value,
         the value will be 0.
         The value of this object is the actual current in 
         AMP * 10. You need to translate the readed value
         (Ex. : value is 5, the current is 0.5 AMP.)
         Clear this value, set it with Zero value. 
         This OID is obsoleted. The value can be retrieved
         from pmPowerMgmtPDUTableCurrentMax, 
         pmPowerMgmtPhasesTableCurrentMax, or 
         pmPowerMgmtOutletsTableCurrentMax"
::= { pmPowerMgmtPDUTableEntry 15 }

pmPowerMgmtPDUTableTemperatureNOS OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Number of temperature sensors in the PDU."
::= { pmPowerMgmtPDUTableEntry 16 }

pmPowerMgmtPDUTableTemperature1Value OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Temperature of this PM unit in Celsius degrees.
         The value of this object is the actual temperature in 
         degrees C * 10. You need to translate the readed value
        (Ex. : value is 240, the temperature is 24 Celsius.) 
         If the temperature measurement is not installed this 
         value will be 0.
        Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)." 
::= { pmPowerMgmtPDUTableEntry 17 }

pmPowerMgmtPDUTableTemperature1Max OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             obsolete
        DESCRIPTION
        "Maximum temperature detected in this PM unit in Celsius degrees.
        The value will be Zero when the PDU does not have support for maximum value.
         The value of this object is the actual temperature in 
         degrees C * 10. You need to translate the readed value
        (Ex. : value is 240, the temperature is 24 Celsius.) 
         If the temperature measurement is not installed this 
         value will be 0.
         Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
        Set with Zero value to clear the max. temperature." 
::= { pmPowerMgmtPDUTableEntry 18 }

pmPowerMgmtPDUTableTemperature2Value OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Temperature of this PM unit in Celsius degrees.
         The value of this object is the actual temperature in 
         degrees C * 10. You need to translate the readed value
         (Ex. : value is 240, the temperature is 24 Celsius.) 
         If the temperature measurement is not installed this 
         value will be 0.
          Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)." 
::= { pmPowerMgmtPDUTableEntry 19 }

pmPowerMgmtPDUTableTemperature2Max OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             obsolete
        DESCRIPTION
        "Maximum temperature detected in this PM unit in Celsius degrees.
         The value will be Zero when the PDU does not have support for maximum value.
         The value of this object is the actual temperature in 
         degrees C * 10. You need to translate the readed value
         (Ex. : value is 240, the temperature is 24 Celsius.) 
         If the temperature measurement is not installed this 
         value will be 0.
         Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
         Set with Zero value to clear the max. temperature." 
::= { pmPowerMgmtPDUTableEntry 20 }

pmPowerMgmtPDUTableTemperature3Value OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Temperature of this PM unit in Celsius degrees.
        The value of this object is the actual temperature in 
        degrees C * 10. You need to translate the readed value
        (Ex. : value is 240, the temperature is 24 Celsius.) 
        If the temperature measurement is not installed this 
        value will be 0.
        Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)." 
::= { pmPowerMgmtPDUTableEntry 21 }

pmPowerMgmtPDUTableTemperature3Max OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             obsolete
        DESCRIPTION
        "Maximum temperature detected in this PM unit in Celsius degrees.
        The value will be Zero when the PDU does not have support for maximum value.
         The value of this object is the actual temperature in 
         degrees C * 10. You need to translate the readed value
         (Ex. : value is 240, the temperature is 24 Celsius.) 
         If the temperature measurement is not installed this 
         value will be 0.
         Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
         Set with Zero value to clear the max. temperature." 
::= { pmPowerMgmtPDUTableEntry 22 }

pmPowerMgmtPDUTableHumidityNOS OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Number of humidity sensors in the PDU."
::= { pmPowerMgmtPDUTableEntry 23 }

pmPowerMgmtPDUTableHumidity1Value OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Humidity of this PM unit .
         If the humidity measurement is not installed this 
         value will be 0." 
::= {  pmPowerMgmtPDUTableEntry 24 }

pmPowerMgmtPDUTableHumidity1Max OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             obsolete
        DESCRIPTION
        "Maximum humidity detected in this PM unit.
         If the humidity measurement  is not installed  or the PDU does not have support for maximum value this 
         value will be 0.
         Set with Zero value to clear the max. temperature." 
::= {  pmPowerMgmtPDUTableEntry 25 }

pmPowerMgmtPDUTableHumidity2Value OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Humidity of this PM unit .
         If the humidity measurement is not installed this 
         value will be 0." 
::= {  pmPowerMgmtPDUTableEntry 26 }

pmPowerMgmtPDUTableHumidity2Max OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             obsolete
        DESCRIPTION
        "Maximum humidity detected in this PM unit.
         If the humidity measurement  is not installed  or the PDU does not have support for maximum value this 
         value will be 0.
         Set with Zero value to clear the max. temperature." 
::= {  pmPowerMgmtPDUTableEntry 27 }

pmPowerMgmtPDUTableHumidity3Value OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Humidity of this PM unit .
         If the humidity measurement is not installed this 
         value will be 0." 
::= {  pmPowerMgmtPDUTableEntry 28 }

pmPowerMgmtPDUTableHumidity3Max OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             obsolete
        DESCRIPTION
        "Maximum humidity detected in this PM unit.
         If the humidity measurement  is not installed  or the PDU does not have support for maximum value this 
         value will be 0.
         Set with Zero value to clear the max. temperature." 
::= {  pmPowerMgmtPDUTableEntry 29 }

pmPowerMgmtPDUTableVoltageNOS OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Number of voltage sensors in the PDU."
::= { pmPowerMgmtPDUTableEntry 30 }

pmPowerMgmtPDUTableVoltage1Value OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Voltage of this sensor in this PDU unit. 
         This OID is obsoleted. The value can be retrieved
         from pmPowerMgmtPDUTableVoltageValue, 
         pmPowerMgmtPhasesTableVoltageValue, or 
         pmPowerMgmtOutletsTableVoltageValue"
::= { pmPowerMgmtPDUTableEntry 31 }

pmPowerMgmtPDUTableVoltage1Max OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             obsolete
        DESCRIPTION
        "Maximum voltage of this sensor in this PDU unit.
         Set with Zero value to clear the maximum voltage. 
         This OID is obsoleted. The value can be retrieved
         from pmPowerMgmtPDUTableVoltageMax, 
         pmPowerMgmtPhasesTableVoltageMax, or 
         pmPowerMgmtOutletsTableVoltageMax"
::= { pmPowerMgmtPDUTableEntry 32 }

pmPowerMgmtPDUTableVoltage2Value OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Voltage of this sensor in this PDU unit. 
         This OID is obsoleted. The value can be retrieved
         from pmPowerMgmtPDUTableVoltageValue, 
         pmPowerMgmtPhasesTableVoltageValue, or 
         pmPowerMgmtOutletsTableVoltageValue"
::= { pmPowerMgmtPDUTableEntry 33 }

pmPowerMgmtPDUTableVoltage2Max OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             obsolete
        DESCRIPTION
        "Maximum voltage of this sensor in this PDU unit.
         Set with Zero value to clear the maximum voltage. 
         This OID is obsoleted. The value can be retrieved
         from pmPowerMgmtPDUTableVoltageMax, 
         pmPowerMgmtPhasesTableVoltageMax, or 
         pmPowerMgmtOutletsTableVoltageMax"
::= { pmPowerMgmtPDUTableEntry 34 }

pmPowerMgmtPDUTableVoltage3Value OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             obsolete
        DESCRIPTION
        "Voltage of this sensor in this PDU unit. 
         This OID is obsoleted. The value can be retrieved
         from pmPowerMgmtPDUTableVoltageValue, 
         pmPowerMgmtPhasesTableVoltageValue, or 
         pmPowerMgmtOutletsTableVoltageValue"
::= { pmPowerMgmtPDUTableEntry 35 }

pmPowerMgmtPDUTableVoltage3Max OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-write
        STATUS             obsolete
        DESCRIPTION
        "Maximum voltage of this sensor in this PDU unit.
         Set with Zero value to clear the maximum voltage. 
         This OID is obsoleted. The value can be retrieved
         from pmPowerMgmtPDUTableVoltageMax, 
         pmPowerMgmtPhasesTableVoltageMax, or 
         pmPowerMgmtOutletsTableVoltageMax"
::= { pmPowerMgmtPDUTableEntry 36 }

pmPowerMgmtPDUTableNumberOfPhases OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of phases of the PDU."
::= { pmPowerMgmtPDUTableEntry 37 }

pmPowerMgmtPDUTableNumberOfBanks OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of banks in the PDU."
::= { pmPowerMgmtPDUTableEntry 38 }

pmPowerMgmtPDUTableNumberOfSensors OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of sensors in the PDU."
::= { pmPowerMgmtPDUTableEntry 40 }

pmPowerMgmtPDUTableFactoryDefault OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "A set value of 2 will set the PDU to factory default settings.
         noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the factory default command is sent to the PDU."
::= { pmPowerMgmtPDUTableEntry 41 }

pmPowerMgmtPDUTableColdStartDelay OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS        read-write
        STATUS            current
        DESCRIPTION
        "PDUs cold start delay in whole seconds (0-60).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 42 }

pmPowerMgmtPDUTableReboot OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reboot(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "A set value of power*(2) will send command to PDU.
         noAction(1) = always returned in a GET. Does nothing if SET.
         reboot(2)  = when SET the reboot command is sent to PDU."
::= { pmPowerMgmtPDUTableEntry 43 }

pmPowerMgmtPDUTableMaxCurrent OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of current allowed in the PDU (A x 10)."
::= { pmPowerMgmtPDUTableEntry 44 }

pmPowerMgmtPDUTableAlarm OBJECT-TYPE
        SYNTAX INTEGER {
            normal (1),
            blow-fuse (2),
            hw-ocp (3),
            high-critical (4),
            high-warning (5),
            low-warning (6),
            low-critical (7)
        }
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Show the PDU alarm status.
                            Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 45 }

--@ Note: Intentionally left space for future expansion (thanks!)
pmPowerMgmtPDUTableCurrentValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of current in the PDU (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 50 }

pmPowerMgmtPDUTableCurrentMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of current in the PDU (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 51 }

pmPowerMgmtPDUTableCurrentMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of current in the PDU (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 52 }

pmPowerMgmtPDUTableCurrentAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of current in the PDU (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 53 }

pmPowerMgmtPDUTableCurrentReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPDUTableEntry 54 }

pmPowerMgmtPDUTablePowerValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of power in the PDU (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 60 }

pmPowerMgmtPDUTablePowerMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of power in the PDU (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 61 }

pmPowerMgmtPDUTablePowerMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of power in the PDU (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 62 }

pmPowerMgmtPDUTablePowerAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of power in the PDU (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 63 }

pmPowerMgmtPDUTablePowerReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPDUTableEntry 64 }

pmPowerMgmtPDUTablePowerType OBJECT-TYPE
        SYNTAX       INTEGER {
            none-sensor (0),
            estimated (1),
            measured (2)
        } 
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Type of power values.
                            Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 65 }

pmPowerMgmtPDUTableVoltageValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of voltage in the PDU (V).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 70 }

pmPowerMgmtPDUTableVoltageMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of voltage in the PDU (V).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 71 }

pmPowerMgmtPDUTableVoltageMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of voltage in the PDU (V).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 72 }

pmPowerMgmtPDUTableVoltageAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of voltage in the PDU (V).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 73 }

pmPowerMgmtPDUTableVoltageReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPDUTableEntry 74 }

pmPowerMgmtPDUTableVoltageType OBJECT-TYPE
        SYNTAX       INTEGER {
            none-sensor (0),
            estimated (1),
            measured (2)
        } 
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Type of voltage values.
                            Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 75 }

pmPowerMgmtPDUTablePowerFactorValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of power factor in the PDU (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 80 }

pmPowerMgmtPDUTablePowerFactorMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of power factor in the PDU (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 81 }

pmPowerMgmtPDUTablePowerFactorMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of power factor in the PDU (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 82 }

pmPowerMgmtPDUTablePowerFactorAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of power factor in the PDU (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 83 }

pmPowerMgmtPDUTablePowerFactorReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPDUTableEntry 84 }

pmPowerMgmtPDUTablePowerFactorType OBJECT-TYPE
        SYNTAX       INTEGER {
            none-sensor (0),
            estimated (1),
            measured (2)
        } 
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Type of power values.
                            Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 85 }

pmPowerMgmtPDUTablePowerControl OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                powerOn(2),
                powerOff(3),
                powerCycle(4)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "A set value of power*(2-4) will send command to PDU.
         noAction(1) = always returned in a GET. Does nothing if SET.
         powerOn(2)  = when SET the power On command is sent to PDU.
         powerOff(3) = when SET the power Off command is sent to PDU.
         powerCycle(4)=when SET the power cycle command is sent to PDU.
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 90 }

pmPowerMgmtPDUTableResetOCP OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "A set value of power*(2) will send command to PDU.
         noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU.
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 91 }

pmPowerMgmtPDUTableCurrentHighCritical OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS        read-write
        STATUS            current
        DESCRIPTION
        "outlet high critical (alarm) current threshold (A x 10).
         Set fails if value is lower that CurrentHighWarning.
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 100 }

pmPowerMgmtPDUTableCurrentHighWarning OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "outlet high warning current threshold (A x 10).
         Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 101 }

pmPowerMgmtPDUTableCurrentLowWarning OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "outlet low warning current threshold (A x 10).
         Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 102 }

pmPowerMgmtPDUTableCurrentLowCritical OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "outlet low critical current threshold (A x 10).
         Set fails if value is higher than CurrentLowWarning.
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 103 }

pmPowerMgmtPDUTableEnergyValue OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "pdu energy value (Wh).
         Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 105 }

pmPowerMgmtPDUTableEnergyStartTime OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "time at which energy calculation commenced (ISO8601 format).
         Returns N/A if not applicable."
::= { pmPowerMgmtPDUTableEntry 106 }

pmPowerMgmtPDUTableEnergyReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPDUTableEntry 107 }

pmPowerMgmtTotalNumberOfOutlets OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of outlets managed by the appliance."
::= { pmPowerMgmt 4 }

pmPowerMgmtOutletsTable OBJECT-TYPE
        SYNTAX             SEQUENCE OF PmPowerMgmtOutletsTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION
        "This table contains the information about outlets."
::= { pmPowerMgmt 5 }
 
pmPowerMgmtOutletsTableEntry OBJECT-TYPE
        SYNTAX             PmPowerMgmtOutletsTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION                
        "each entry has the information about the outlet."
        INDEX             { pmPowerMgmtOutletsTablePortNumber,
                            pmPowerMgmtOutletsTablePduNumber,
                            pmPowerMgmtOutletsTableNumber }
::= { pmPowerMgmtOutletsTable 1 }

PmPowerMgmtOutletsTableEntry ::= SEQUENCE  {
        pmPowerMgmtOutletsTablePortNumber          InterfaceIndex,   -- serial port #
        pmPowerMgmtOutletsTablePduNumber           InterfaceIndex,     
        pmPowerMgmtOutletsTableNumber              InterfaceIndex,   -- outlet number in PDU
        pmPowerMgmtOutletsTableName                DisplayString,    -- outlet name
        pmPowerMgmtOutletsTableStatus              INTEGER,          -- outlet status
        pmPowerMgmtOutletsTablePowerControl        INTEGER,          -- manage the outlet
        pmPowerMgmtOutletsTablePortName            DisplayString,    -- serial port name
        pmPowerMgmtOutletsTablePduId               DisplayString,    -- PDU ID
        pmPowerMgmtOutletsTablePostOnDelay        Integer32,        -- outlet post on delay delay/post power on
        pmPowerMgmtOutletsTablePostOffDelay         Integer32,        -- outlet post off delay/post power off
        pmPowerMgmtOutletsTableAlarm               INTEGER,          -- outlet alarm status
        pmPowerMgmtOutletsTableCurrentValue        Integer32,        -- actual value for current of the sensor
        pmPowerMgmtOutletsTableCurrentMax          Integer32,        -- max value for current
        pmPowerMgmtOutletsTableCurrentMin          Integer32,        -- min value for current
        pmPowerMgmtOutletsTableCurrentAvg          Integer32,        -- average value for current
        pmPowerMgmtOutletsTableCurrentReset        INTEGER,          -- reset the current stats
        pmPowerMgmtOutletsTablePowerValue          Integer32,        -- actual value for power
        pmPowerMgmtOutletsTablePowerMax            Integer32,        -- max value for power
        pmPowerMgmtOutletsTablePowerMin            Integer32,        -- min value for power
        pmPowerMgmtOutletsTablePowerAvg            Integer32,        -- average value for power
        pmPowerMgmtOutletsTablePowerReset          INTEGER,          -- reset the power stats
        pmPowerMgmtOutletsTablePowerType           INTEGER,          -- power type
        pmPowerMgmtOutletsTableVoltageValue        Integer32,        -- actual value for voltage
        pmPowerMgmtOutletsTableVoltageMax          Integer32,        -- max value for voltage
        pmPowerMgmtOutletsTableVoltageMin          Integer32,        -- min value for voltage
        pmPowerMgmtOutletsTableVoltageAvg          Integer32,        -- average value for voltage
        pmPowerMgmtOutletsTableVoltageReset        INTEGER,          -- reset the voltage stats
        pmPowerMgmtOutletsTableVoltageType         INTEGER,          -- type of voltage measurement
        pmPowerMgmtOutletsTablePowerFactorValue    Integer32,        -- actual value for powerfactor
        pmPowerMgmtOutletsTablePowerFactorMax      Integer32,        -- max value for powerfactor
        pmPowerMgmtOutletsTablePowerFactorMin      Integer32,        -- min value for powerfactor
        pmPowerMgmtOutletsTablePowerFactorAvg      Integer32,        -- average value for powerfactor
        pmPowerMgmtOutletsTablePowerFactorReset    INTEGER,          -- reset the powerfactor stats
        pmPowerMgmtOutletsTablePowerFactorType     INTEGER,          -- power factor type
        pmPowerMgmtOutletsTableCurrentHighCritical Integer32,        -- outlet current high critical threshold
        pmPowerMgmtOutletsTableCurrentHighWarning  Integer32,        -- outlet current high warning threshold
        pmPowerMgmtOutletsTableCurrentLowWarning   Integer32,        -- outlet current low warning threshold
        pmPowerMgmtOutletsTableCurrentLowCritical  Integer32,        -- outlet current low critical threshold
        pmPowerMgmtOutletsTableEnergyValue         Integer32,        -- Energy value
        pmPowerMgmtOutletsTableEnergyStartTime     DisplayString,    -- time at which energy calculation commenced
        pmPowerMgmtOutletsTableEnergyReset         INTEGER           -- reset energy calculation and start time to now
}

pmPowerMgmtOutletsTablePortNumber OBJECT-TYPE
        SYNTAX             InterfaceIndex
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Serial Port number."
::= { pmPowerMgmtOutletsTableEntry 1 }

pmPowerMgmtOutletsTablePduNumber OBJECT-TYPE
        SYNTAX             InterfaceIndex
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Index."
::= { pmPowerMgmtOutletsTableEntry 2 }

pmPowerMgmtOutletsTableNumber OBJECT-TYPE
        SYNTAX             InterfaceIndex
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of the outlet in the PDU."
::= { pmPowerMgmtOutletsTableEntry 3 }

pmPowerMgmtOutletsTableName OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "Name of the outlet." 
::= { pmPowerMgmtOutletsTableEntry 4 }

pmPowerMgmtOutletsTableStatus OBJECT-TYPE
        SYNTAX INTEGER {
                off(1),
                on(2),
                offLocked(3),
                onLocked(4),
                offCycle(5),
                onPendingOff(6),
                offPendingOn(7),
                onPendingCycle(8),
                notSet(9),
                onFixed(10),
                offShutdown(11),
                tripped(12)
        }
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Status of the outlet.
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 5 }

pmPowerMgmtOutletsTablePowerControl OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                powerOn(2),
                powerOff(3),
                powerCycle(4),
                powerLock(5),
                powerUnlock(6)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION 
        "A set value of power*(2-6) will send command to PDU.
         noAction(1) = always returned in a GET. Does nothing if SET.
         powerOn(2)  = when SET the power On command is sent to PDU.
         powerOff(3) = when SET the power Off command is sent to PDU.
         powerCycle(4)=when SET the power cycle command is sent to PDU.
         powerLock(5)= when SET the power lock command is sent to PDU.
         powerUnlock(6)=when SET the power unlock command is sent to PDU.
        The powerLock and powerUnlock are valid only for Cyclades-PM PDUs"
::= { pmPowerMgmtOutletsTableEntry 6 }

pmPowerMgmtOutletsTablePortName OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Serial Port Name where the PDU is connected."
::= { pmPowerMgmtOutletsTableEntry 7 }

pmPowerMgmtOutletsTablePduId OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "PDU identification."
::= { pmPowerMgmtOutletsTableEntry 8 }

pmPowerMgmtOutletsTablePostOnDelay OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "post on delay for the outlet (seconds x 10)
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 9 }

pmPowerMgmtOutletsTablePostOffDelay OBJECT-TYPE
        SYNTAX Integer32 
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "post off delay for the outlet (seconds x 10)
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 10 }

pmPowerMgmtOutletsTableAlarm OBJECT-TYPE
        SYNTAX       INTEGER {
            normal (1),
            blow-fuse (2),
            hw-ocp (3),
            high-critical (4),
            high-warning (5),
            low-warning (6),
            low-critical (7)
        } 
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Show the outlet alarm status.
                            Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 45 }

--@ Note: Intentionally left space for future expansion
pmPowerMgmtOutletsTableCurrentValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of current in the outlet (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 50 }

pmPowerMgmtOutletsTableCurrentMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of current in the outlet (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 51 }

pmPowerMgmtOutletsTableCurrentMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of current in the outlet (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 52 }

pmPowerMgmtOutletsTableCurrentAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of current in the outlet (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 53 }

pmPowerMgmtOutletsTableCurrentReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtOutletsTableEntry 54 }

pmPowerMgmtOutletsTablePowerValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of power in the outlet (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 60 }

pmPowerMgmtOutletsTablePowerMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of power in the outlet (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 61 }

pmPowerMgmtOutletsTablePowerMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of power in the outlet (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 62 }

pmPowerMgmtOutletsTablePowerAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of power in the outlet (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 63 }

pmPowerMgmtOutletsTablePowerReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtOutletsTableEntry 64 }

pmPowerMgmtOutletsTablePowerType OBJECT-TYPE
        SYNTAX       INTEGER {
            none-sensor (0),
            estimated (1),
            measured (2)
        }
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Type of power values.
                            Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 65 }

pmPowerMgmtOutletsTableVoltageValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of voltage in the outlet (V).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 70 }

pmPowerMgmtOutletsTableVoltageMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of voltage in the outlet (V).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 71 }

pmPowerMgmtOutletsTableVoltageMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of voltage in the outlet (V).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 72 }

pmPowerMgmtOutletsTableVoltageAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of voltage in the outlet (V).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 73 }

pmPowerMgmtOutletsTableVoltageReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtOutletsTableEntry 74 }

pmPowerMgmtOutletsTableVoltageType OBJECT-TYPE
        SYNTAX INTEGER {
                none-sensor (0),
                estimated (1),
                measured (2)
        }
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Type of voltage values.
                            Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 75 }

pmPowerMgmtOutletsTablePowerFactorValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of power factor in the outlet (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 80 }

pmPowerMgmtOutletsTablePowerFactorMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of power factor in the outlet (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 81 }

pmPowerMgmtOutletsTablePowerFactorMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of power factor in the outlet (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 82 }

pmPowerMgmtOutletsTablePowerFactorAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of power factor in the outlet (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 83 }

pmPowerMgmtOutletsTablePowerFactorReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtOutletsTableEntry 84 }

pmPowerMgmtOutletsTablePowerFactorType OBJECT-TYPE
        SYNTAX       INTEGER {
            none-sensor (0),
            estimated (1),
            measured (2)
        }
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Type of power factor values.
                            Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 85 }

pmPowerMgmtOutletsTableCurrentHighCritical OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "outlet high critical (alarm) current threshold (A x 10).
         Set fails if value is lower that CurrentHighWarning.
         Returns 0 if not supported." 
::= { pmPowerMgmtOutletsTableEntry 100 }

pmPowerMgmtOutletsTableCurrentHighWarning OBJECT-TYPE
        SYNTAX Integer32  
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "outlet high warning current threshold (A x 10).
         Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 101 }

pmPowerMgmtOutletsTableCurrentLowWarning OBJECT-TYPE
        SYNTAX Integer32  
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "outlet low warning current threshold (A x 10).
         Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 102 }

pmPowerMgmtOutletsTableCurrentLowCritical OBJECT-TYPE
        SYNTAX Integer32  
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "outlet low critical current threshold (A x 10).
         Set fails if value is higher than CurrentLowWarning.
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 103 }

pmPowerMgmtOutletsTableEnergyValue OBJECT-TYPE
        SYNTAX Integer32  
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "outlet energy value (Wh).
         Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 105 }

pmPowerMgmtOutletsTableEnergyStartTime OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "time at which energy calculation commenced (ISO8601 format).
         Returns N/A if not applicable."
::= { pmPowerMgmtOutletsTableEntry 106 }

pmPowerMgmtOutletsTableEnergyReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtOutletsTableEntry 107 }

pmPowerMgmtNumberOfOutletGroup OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of configured group of outlets."
::= { pmPowerMgmt 6 }

pmPowerMgmtGroupTable OBJECT-TYPE
        SYNTAX             SEQUENCE OF PmPowerMgmtGroupTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION
        "This table contains the information about group of outlets."
::= { pmPowerMgmt 7 }
 
pmPowerMgmtGroupTableEntry  OBJECT-TYPE
        SYNTAX             PmPowerMgmtGroupTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION                
        "each entry has the information about group of outlets."
        INDEX              { pmPowerMgmtGroupTableIndex }
::= { pmPowerMgmtGroupTable 1 }

PmPowerMgmtGroupTableEntry ::= SEQUENCE  {
        pmPowerMgmtGroupTableIndex           InterfaceIndexOrZero,      
        pmPowerMgmtGroupTableName            DisplayString, -- group name
        pmPowerMgmtGroupTableStatus          INTEGER,       -- group status
        pmPowerMgmtGroupTablePowerControl    INTEGER        -- manage the group        
}

pmPowerMgmtGroupTableIndex OBJECT-TYPE
        SYNTAX             InterfaceIndexOrZero
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Index of the group."
::= { pmPowerMgmtGroupTableEntry 1 }

pmPowerMgmtGroupTableName OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Name of the group of outlets." 
::= { pmPowerMgmtGroupTableEntry 2 }

pmPowerMgmtGroupTableStatus OBJECT-TYPE
        SYNTAX INTEGER {
                off(1),
                on(2)
        }
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Status of the group of outlet."
::= { pmPowerMgmtGroupTableEntry 3 }

pmPowerMgmtGroupTablePowerControl OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                powerOn(2),
                powerOff(3),
                powerCycle(4)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION 
        "A set value of power*(2-4) will send command to PDU.
         noAction(1) = always returned in a GET. Does nothing if SET.
         powerOn(2)  = when SET the power On command is sent to PDU.
         powerOff(3) = when SET the power Off command is sent to PDU.
         powerCycle(4)=when SET the power cycle command is sent to PDU."
::= { pmPowerMgmtGroupTableEntry 4 }

pmPowerMgmtTotalNumberOfPhases OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of phases managed by the appliance."
::= { pmPowerMgmt 8 }

pmPowerMgmtPhasesTable OBJECT-TYPE
        SYNTAX             SEQUENCE OF PmPowerMgmtPhasesTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION
        "This table contains the information about phases."
::= { pmPowerMgmt 9 }
 
pmPowerMgmtPhasesTableEntry  OBJECT-TYPE
        SYNTAX             PmPowerMgmtPhasesTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION                
        "each entry has the information about the phases."
        INDEX             { pmPowerMgmtPhasesTablePortNumber,
                            pmPowerMgmtPhasesTablePduNumber,
                            pmPowerMgmtPhasesTableNumber }
::= { pmPowerMgmtPhasesTable 1 }

PmPowerMgmtPhasesTableEntry ::= SEQUENCE  {
        pmPowerMgmtPhasesTablePortNumber          InterfaceIndex,   -- serial port #
        pmPowerMgmtPhasesTablePduNumber           InterfaceIndex,     
        pmPowerMgmtPhasesTableNumber              InterfaceIndex,   -- phase number in PDU
        pmPowerMgmtPhasesTableName                DisplayString,    -- phase sysname
        pmPowerMgmtPhasesTablePortName            DisplayString,    -- serial port name
        pmPowerMgmtPhasesTablePduId               DisplayString,    -- PDU ID
        pmPowerMgmtPhasesTableAlarm               INTEGER,          -- phase alarm status
        pmPowerMgmtPhasesTableCurrentValue        Integer32,        -- actual value for current of the sensor
        pmPowerMgmtPhasesTableCurrentMax          Integer32,        -- max value for current
        pmPowerMgmtPhasesTableCurrentMin          Integer32,        -- min value for current
        pmPowerMgmtPhasesTableCurrentAvg          Integer32,        -- average value for current
        pmPowerMgmtPhasesTableCurrentReset        INTEGER,          -- reset the current stats
        pmPowerMgmtPhasesTablePowerValue          Integer32,        -- actual value for power
        pmPowerMgmtPhasesTablePowerMax            Integer32,        -- max value for power
        pmPowerMgmtPhasesTablePowerMin            Integer32,        -- min value for power
        pmPowerMgmtPhasesTablePowerAvg            Integer32,        -- average value for power
        pmPowerMgmtPhasesTablePowerReset          INTEGER,          -- reset the power stats
        pmPowerMgmtPhasesTablePowerType           INTEGER,          -- power type
        pmPowerMgmtPhasesTableVoltageValue        Integer32,        -- actual value for voltage
        pmPowerMgmtPhasesTableVoltageMax          Integer32,        -- max value for voltage
        pmPowerMgmtPhasesTableVoltageMin          Integer32,        -- min value for voltage
        pmPowerMgmtPhasesTableVoltageAvg          Integer32,        -- average value for voltage
        pmPowerMgmtPhasesTableVoltageReset        INTEGER,          -- reset the voltage stats
        pmPowerMgmtPhasesTableVoltageType         INTEGER,          -- voltage type
        pmPowerMgmtPhasesTablePowerFactorValue    Integer32,        -- actual value for powerfactor
        pmPowerMgmtPhasesTablePowerFactorMax      Integer32,        -- max value for powerfactor
        pmPowerMgmtPhasesTablePowerFactorMin      Integer32,        -- min value for powerfactor
        pmPowerMgmtPhasesTablePowerFactorAvg      Integer32,        -- average value for powerfactor
        pmPowerMgmtPhasesTablePowerFactorReset    INTEGER,          -- reset the powerfactor stats
        pmPowerMgmtPhasesTablePowerFactorType     INTEGER,          -- power factor type
        pmPowerMgmtPhasesTableCurrentHighCritical Integer32,        -- outlet current high critical threshold
        pmPowerMgmtPhasesTableCurrentHighWarning  Integer32,        -- outlet current high warning threshold
        pmPowerMgmtPhasesTableCurrentLowWarning   Integer32,        -- outlet current low warning threshold
        pmPowerMgmtPhasesTableCurrentLowCritical  Integer32        -- outlet current low critical threshold
}

pmPowerMgmtPhasesTablePortNumber OBJECT-TYPE
        SYNTAX             InterfaceIndex
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Serial Port number."
::= { pmPowerMgmtPhasesTableEntry 1 }

pmPowerMgmtPhasesTablePduNumber OBJECT-TYPE
        SYNTAX             InterfaceIndex
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Index."
::= { pmPowerMgmtPhasesTableEntry 2 }

pmPowerMgmtPhasesTableNumber OBJECT-TYPE
        SYNTAX             InterfaceIndex
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of the phase in the PDU."
::= { pmPowerMgmtPhasesTableEntry 3 }

pmPowerMgmtPhasesTableName OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Name of the phase.
         Returns N/A if not applicable." 
::= { pmPowerMgmtPhasesTableEntry 4 }

pmPowerMgmtPhasesTablePortName OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Serial Port Name where the PDU is connected."
::= { pmPowerMgmtPhasesTableEntry 5 }

pmPowerMgmtPhasesTablePduId OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "PDU identification."
::= { pmPowerMgmtPhasesTableEntry 6 }

pmPowerMgmtPhasesTableAlarm OBJECT-TYPE
        SYNTAX       INTEGER {
            normal (1),
            blow-fuse (2),
            hw-ocp (3),
            high-critical (4),
            high-warning (5),
            low-warning (6),
            low-critical (7)
        } 
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Show the phase alarm status.
                            Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 45 }

--@ Note: Intentionally left space for future expansion
pmPowerMgmtPhasesTableCurrentValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of current in the phase (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 50 }

pmPowerMgmtPhasesTableCurrentMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of current in the phase (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 51 }

pmPowerMgmtPhasesTableCurrentMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of current in the phase (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 52 }

pmPowerMgmtPhasesTableCurrentAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of current in the phase (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 53 }

pmPowerMgmtPhasesTableCurrentReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPhasesTableEntry 54 }

pmPowerMgmtPhasesTablePowerValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of power in the phase (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 60 }

pmPowerMgmtPhasesTablePowerMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of power in the phase (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 61 }

pmPowerMgmtPhasesTablePowerMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of power in the phase (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 62 }

pmPowerMgmtPhasesTablePowerAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of power in the phase (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 63 }

pmPowerMgmtPhasesTablePowerReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPhasesTableEntry 64 }

pmPowerMgmtPhasesTablePowerType OBJECT-TYPE
        SYNTAX       INTEGER {
            none-sensor (0),
            estimated (1),
            measured (2)
        }
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Type of power values.
                            Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 65 }

pmPowerMgmtPhasesTableVoltageValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of voltage in the phase (V).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 70 }

pmPowerMgmtPhasesTableVoltageMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of voltage in the phase (V).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 71 }

pmPowerMgmtPhasesTableVoltageMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of voltage in the phase (V).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 72 }

pmPowerMgmtPhasesTableVoltageAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of voltage in the phase (V).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 73 }

pmPowerMgmtPhasesTableVoltageReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPhasesTableEntry 74 }

pmPowerMgmtPhasesTableVoltageType OBJECT-TYPE
        SYNTAX       INTEGER {
            none-sensor (0),
            estimated (1),
            measured (2)
        }
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Type of voltage values.
                            Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 75 }

pmPowerMgmtPhasesTablePowerFactorValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of power factor in the phase (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 80 }

pmPowerMgmtPhasesTablePowerFactorMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of power factor in the phase (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 81 }

pmPowerMgmtPhasesTablePowerFactorMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of power factor in the phase (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 82 }

pmPowerMgmtPhasesTablePowerFactorAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of power factor in the phase (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 83 }

pmPowerMgmtPhasesTablePowerFactorReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPhasesTableEntry 84 }

pmPowerMgmtPhasesTablePowerFactorType OBJECT-TYPE
        SYNTAX       INTEGER {
            none-sensor (0),
            estimated (1),
            measured (2)
        }
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Type of power factor values.
                            Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 85 }

pmPowerMgmtPhasesTableCurrentHighCritical OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "phase high critical (alarm) current threshold (A x 10).
         Set fails if value is lower that CurrentHighWarning.
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 100 }

pmPowerMgmtPhasesTableCurrentHighWarning OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "phase high warning current threshold (A x 10).
         Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 101 }

pmPowerMgmtPhasesTableCurrentLowWarning OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "phase low warning current threshold (A x 10).
         Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 102 }

pmPowerMgmtPhasesTableCurrentLowCritical OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "phase low critical current threshold (A x 10).
         Set fails if value is higher than CurrentLowWarning.
         Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 103 }
 
--@ BANKS

pmPowerMgmtTotalNumberOfBanks OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of banks managed by the appliance."
::= { pmPowerMgmt 10 }

pmPowerMgmtBanksTable OBJECT-TYPE
        SYNTAX             SEQUENCE OF PmPowerMgmtBanksTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION
        "This table contains the information about banks."
::= { pmPowerMgmt 11 }
 
pmPowerMgmtBanksTableEntry OBJECT-TYPE
        SYNTAX             PmPowerMgmtBanksTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION                
        "each entry has the information about the banks."
        INDEX             { pmPowerMgmtBanksTablePortNumber,
                            pmPowerMgmtBanksTablePduNumber,
                            pmPowerMgmtBanksTableNumber }
::= { pmPowerMgmtBanksTable 1 }

PmPowerMgmtBanksTableEntry ::= SEQUENCE  {
        pmPowerMgmtBanksTablePortNumber          InterfaceIndex,   -- serial port #
        pmPowerMgmtBanksTablePduNumber           InterfaceIndex,     
        pmPowerMgmtBanksTableNumber              InterfaceIndex,   -- bank number in PDU
        pmPowerMgmtBanksTableName                DisplayString,    -- bank sysname
        pmPowerMgmtBanksTablePortName            DisplayString,    -- serial port name
        pmPowerMgmtBanksTablePduId               DisplayString,    -- PDU ID
        pmPowerMgmtBanksTableAlarm               INTEGER,          -- bank alarm status
        pmPowerMgmtBanksTableCurrentValue        Integer32,        -- actual value for current of the sensor
        pmPowerMgmtBanksTableCurrentMax          Integer32,        -- max value for current
        pmPowerMgmtBanksTableCurrentMin          Integer32,        -- min value for current
        pmPowerMgmtBanksTableCurrentAvg          Integer32,        -- average value for current
        pmPowerMgmtBanksTableCurrentReset        INTEGER,          -- reset current stats
        pmPowerMgmtBanksTablePowerValue          Integer32,        -- actual value for power
        pmPowerMgmtBanksTablePowerMax            Integer32,        -- max value for power
        pmPowerMgmtBanksTablePowerMin            Integer32,        -- min value for power
        pmPowerMgmtBanksTablePowerAvg            Integer32,        -- average value for power
        pmPowerMgmtBanksTablePowerReset          INTEGER,          -- reset power stats
        pmPowerMgmtBanksTablePowerType           INTEGER,          -- power type
        pmPowerMgmtBanksTableVoltageValue        Integer32,        -- actual value for voltage
        pmPowerMgmtBanksTableVoltageMax          Integer32,        -- max value for voltage
        pmPowerMgmtBanksTableVoltageMin          Integer32,        -- min value for voltage
        pmPowerMgmtBanksTableVoltageAvg          Integer32,        -- average value for voltage
        pmPowerMgmtBanksTableVoltageReset        INTEGER,          -- reset voltage stats
        pmPowerMgmtBanksTableVoltageType         INTEGER,          -- voltage type
        pmPowerMgmtBanksTablePowerFactorValue    Integer32,        -- actual value for powerfactor
        pmPowerMgmtBanksTablePowerFactorMax      Integer32,        -- max value for powerfactor
        pmPowerMgmtBanksTablePowerFactorMin      Integer32,        -- min value for powerfactor
        pmPowerMgmtBanksTablePowerFactorAvg      Integer32,        -- average value for powerfactor
        pmPowerMgmtBanksTablePowerFactorReset    INTEGER,          -- reset powerfactor stats
        pmPowerMgmtBanksTablePowerFactorType     INTEGER,          -- power factor type
        pmPowerMgmtBanksTableCurrentHighCritical Integer32,        -- outlet current high critical threshold
        pmPowerMgmtBanksTableCurrentHighWarning  Integer32,        -- outlet current high warning threshold
        pmPowerMgmtBanksTableCurrentLowWarning   Integer32,        -- outlet current low warning threshold
        pmPowerMgmtBanksTableCurrentLowCritical  Integer32,        -- outlet current low critical threshold
        pmPowerMgmtBanksTableEnergyValue         Integer32,        -- Energy value
        pmPowerMgmtBanksTableEnergyStartTime     DisplayString,    -- time at which energy calculation commenced
        pmPowerMgmtBanksTableEnergyReset         INTEGER           -- reset energy calculation and start time to now
}

pmPowerMgmtBanksTablePortNumber OBJECT-TYPE
        SYNTAX             InterfaceIndex
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Serial Port number."
::= { pmPowerMgmtBanksTableEntry 1 }

pmPowerMgmtBanksTablePduNumber OBJECT-TYPE
        SYNTAX             InterfaceIndex
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Index."
::= { pmPowerMgmtBanksTableEntry 2 }

pmPowerMgmtBanksTableNumber OBJECT-TYPE
        SYNTAX             InterfaceIndex
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of the bank in the PDU."
::= { pmPowerMgmtBanksTableEntry 3 }

pmPowerMgmtBanksTableName OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Name of the bank." 
::= { pmPowerMgmtBanksTableEntry 4 }

pmPowerMgmtBanksTablePortName OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Serial Port Name where the PDU is connected."
::= { pmPowerMgmtBanksTableEntry 5 }

pmPowerMgmtBanksTablePduId OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "PDU identification."
::= { pmPowerMgmtBanksTableEntry 6 }

pmPowerMgmtBanksTableAlarm OBJECT-TYPE
        SYNTAX       INTEGER {
            normal (1),
            blow-fuse (2),
            hw-ocp (3),
            high-critical (4),
            high-warning (5),
            low-warning (6),
            low-critical (7)
        } 
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Show the bank alarm status.
                            Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 45 }


--@ Note: Intentionally left space for future expansion
pmPowerMgmtBanksTableCurrentValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of current in the bank (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 50 }

pmPowerMgmtBanksTableCurrentMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of current in the bank (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 51 }

pmPowerMgmtBanksTableCurrentMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of current in the bank (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 52 }

pmPowerMgmtBanksTableCurrentAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of current in the bank (A x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 53 }

pmPowerMgmtBanksTableCurrentReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtBanksTableEntry 54 }

pmPowerMgmtBanksTablePowerValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of power in the bank (W x 10).
          Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 60 }

pmPowerMgmtBanksTablePowerMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of power in the bank (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 61 }

pmPowerMgmtBanksTablePowerMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of power in the bank (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 62 }

pmPowerMgmtBanksTablePowerAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of power in the bank (W x 10).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 63 }

pmPowerMgmtBanksTablePowerReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtBanksTableEntry 64 }

pmPowerMgmtBanksTablePowerType OBJECT-TYPE
        SYNTAX       INTEGER {
            none-sensor (0),
            estimated (1),
            measured (2)
        }
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Type of power values.
                            Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 65 }

pmPowerMgmtBanksTableVoltageValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of voltage in the bank (V).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 70 }

pmPowerMgmtBanksTableVoltageMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of voltage in the bank (V).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 71 }

pmPowerMgmtBanksTableVoltageMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of voltage in the bank (V).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 72 }

pmPowerMgmtBanksTableVoltageAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of voltage in the bank (V).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 73 }

pmPowerMgmtBanksTableVoltageReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtBanksTableEntry 74 }

pmPowerMgmtBanksTableVoltageType OBJECT-TYPE
        SYNTAX       INTEGER {
            none-sensor (0),
            estimated (1),
            measured (2)
        }
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Type of voltage values.
                            Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 75 }

pmPowerMgmtBanksTablePowerFactorValue OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of power factor in the bank (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 80 }

pmPowerMgmtBanksTablePowerFactorMax OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of power factor in the bank (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 81 }

pmPowerMgmtBanksTablePowerFactorMin OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of power factor in the bank (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 82 }

pmPowerMgmtBanksTablePowerFactorAvg OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of power factor in the bank (Pf x 100).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 83 }

pmPowerMgmtBanksTablePowerFactorReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtBanksTableEntry 84 }

pmPowerMgmtBanksTablePowerFactorType OBJECT-TYPE
        SYNTAX       INTEGER {
            none-sensor (0),
            estimated (1),
            measured (2)
        }
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION        "Type of power factor values.
                            Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 85 }

pmPowerMgmtBanksTableCurrentHighCritical OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "bank high critical (alarm) current threshold (A x 10).
         Set fails if value is lower that CurrentHighWarning.
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 100 }

pmPowerMgmtBanksTableCurrentHighWarning OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "bank high warning current threshold (A x 10).
         Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 101 }

pmPowerMgmtBanksTableCurrentLowWarning OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "bank low warning current threshold (A x 10).
         Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 102 }

pmPowerMgmtBanksTableCurrentLowCritical OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "bank low critical current threshold (A x 10).
         Set fails if value is higher than CurrentLowWarning.
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 103 }

pmPowerMgmtBanksTableEnergyValue OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "bank energy value (Wh).
         Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 105 }

pmPowerMgmtBanksTableEnergyStartTime OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "time at which energy calculation commenced (ISO8601 format).
         Returns N/A if not applicable."
::= { pmPowerMgmtBanksTableEntry 106 }

pmPowerMgmtBanksTableEnergyReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to PDU."
::= { pmPowerMgmtBanksTableEntry 107 }

--@ Sensors

pmPowerMgmtTotalNumberOfSensors OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of Sensors managed by the appliance."
::= { pmPowerMgmt 12 }

pmPowerMgmtSensorsTable OBJECT-TYPE
        SYNTAX             SEQUENCE OF PmPowerMgmtSensorsTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION
        "This table contains the information about sensors."
::= { pmPowerMgmt 13 }
 
pmPowerMgmtSensorsTableEntry OBJECT-TYPE
        SYNTAX             PmPowerMgmtSensorsTableEntry
        MAX-ACCESS         not-accessible
        STATUS             current
        DESCRIPTION                
        "each entry has the information about the sensors."
        INDEX             { pmPowerMgmtSensorsTablePortNumber,
                            pmPowerMgmtSensorsTablePduNumber,
                            pmPowerMgmtSensorsTableNumber }
::= { pmPowerMgmtSensorsTable 1 }

PmPowerMgmtSensorsTableEntry ::= SEQUENCE  {
        pmPowerMgmtSensorsTablePortNumber    InterfaceIndex,   -- serial port #
        pmPowerMgmtSensorsTablePduNumber     InterfaceIndex,     
        pmPowerMgmtSensorsTableNumber        InterfaceIndex,   -- sensor number in PDU
        pmPowerMgmtSensorsTableName          DisplayString,    -- sensor name
        pmPowerMgmtSensorsTablePortName      DisplayString,    -- serial port name
        pmPowerMgmtSensorsTablePduId         DisplayString,    -- PDU ID
        pmPowerMgmtSensorsTableType          INTEGER,          -- sensor type
        pmPowerMgmtSensorsTableStatus        INTEGER,          -- digital sensor status
        pmPowerMgmtSensorsTableValue         DisplayString,    -- actual value for current of the sensor
        pmPowerMgmtSensorsTableValueMax      DisplayString,    -- max value for current
        pmPowerMgmtSensorsTableValueMin      DisplayString,    -- min value for current
        pmPowerMgmtSensorsTableValueAvg      DisplayString,    -- average value for current
        pmPowerMgmtSensorsTableValueInt      Integer32,        -- actual value for current of the sensor
        pmPowerMgmtSensorsTableValueMaxInt   Integer32,        -- max value for current
        pmPowerMgmtSensorsTableValueMinInt   Integer32,        -- min value for current
        pmPowerMgmtSensorsTableValueAvgInt   Integer32,        -- average value for current
        pmPowerMgmtSensorsTableValueReset    INTEGER,          -- reset current stats
        pmPowerMgmtSensorsTableHighCritical  Integer32,        -- set/get sensor high critical threshold
        pmPowerMgmtSensorsTableHighWarning   Integer32,        -- set/get sensor high warning threshold
        pmPowerMgmtSensorsTableLowWarning    Integer32,        -- set/get sensor low warning threshold
        pmPowerMgmtSensorsTableLowCritical   Integer32,        -- set/get sensor low critical threshold
        pmPowerMgmtSensorsTableUnit          INTEGER,          -- set/get sensor unit of measurement
        pmPowerMgmtSensorsTableHighCriticalC Integer32,        -- get sensor high critical threshold
        pmPowerMgmtSensorsTableHighWarningC  Integer32,        -- get sensor high warning threshold
        pmPowerMgmtSensorsTableLowWarningC   Integer32,        -- get sensor low warning threshold
        pmPowerMgmtSensorsTableLowCriticalC  Integer32,        -- get sensor low critical threshold
        pmPowerMgmtSensorsTableHighCriticalF Integer32,        -- get sensor high critical threshold
        pmPowerMgmtSensorsTableHighWarningF  Integer32,        -- get sensor high warning threshold
        pmPowerMgmtSensorsTableLowWarningF   Integer32,        -- get sensor low warning threshold
        pmPowerMgmtSensorsTableLowCriticalF  Integer32         -- get sensor low critical threshold
}

pmPowerMgmtSensorsTablePortNumber OBJECT-TYPE
        SYNTAX             InterfaceIndex
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Serial Port number."
::= { pmPowerMgmtSensorsTableEntry 1 }

pmPowerMgmtSensorsTablePduNumber OBJECT-TYPE
        SYNTAX             InterfaceIndex
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Index."
::= { pmPowerMgmtSensorsTableEntry 2 }

pmPowerMgmtSensorsTableNumber OBJECT-TYPE
        SYNTAX             InterfaceIndex
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Number of the sensor in the PDU."
::= { pmPowerMgmtSensorsTableEntry 3 }

pmPowerMgmtSensorsTableName OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "Name of the sensor." 
::= { pmPowerMgmtSensorsTableEntry 4 }

pmPowerMgmtSensorsTablePortName OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Serial Port Name where the PDU is connected."
::= { pmPowerMgmtSensorsTableEntry 5 }

pmPowerMgmtSensorsTablePduId OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "PDU identification."
::= { pmPowerMgmtSensorsTableEntry 6 }

pmPowerMgmtSensorsTableType OBJECT-TYPE
        SYNTAX  INTEGER {
            temp-internal (1),
            temperature (2),
            humidity (3),
            air-flow (4),
            smoke (5),
            dry-concact (6),
            water-level (7),
            motion (8),
            unplugged (9),
            unknown (10)
        }
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "The type of environmental monitor.
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 7 }

pmPowerMgmtSensorsTableStatus OBJECT-TYPE
        SYNTAX  INTEGER {
            normal(1),
            triggered(2),
            not-applicable(3),
            opened(4),
            closed(5)
        }
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Status of digital sensors: Dry-Contact, Water level, Smoke sensor, Motion sensor.
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 8 }


--@ Note: Intentionally left space for future expansion
pmPowerMgmtSensorsTableValue OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of the sensor.
         Returns N/A if not applicable."
::= { pmPowerMgmtSensorsTableEntry 20 }

pmPowerMgmtSensorsTableValueMax OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Maximum value of the sensor.
         Returns N/A if not applicable."
::= { pmPowerMgmtSensorsTableEntry 21 }

pmPowerMgmtSensorsTableValueMin OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Minimum value of the sensor.
         Returns N/A if not applicable."
::= { pmPowerMgmtSensorsTableEntry 22 }

pmPowerMgmtSensorsTableValueAvg OBJECT-TYPE
        SYNTAX             DisplayString
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Average value of the sensor.
         Returns N/A if not applicable."
::= { pmPowerMgmtSensorsTableEntry 23 }

pmPowerMgmtSensorsTableValueInt OBJECT-TYPE
        SYNTAX             Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "Actual value of the sensor.
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 25 }

pmPowerMgmtSensorsTableValueMaxInt OBJECT-TYPE
       SYNTAX             Integer32
       MAX-ACCESS         read-only
       STATUS             current
       DESCRIPTION
       "Maximum value of the sensor.
        Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 26 }

pmPowerMgmtSensorsTableValueMinInt OBJECT-TYPE
       SYNTAX             Integer32
       MAX-ACCESS         read-only
       STATUS             current
       DESCRIPTION
       "Minimum value of the sensor.
        Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 27 }

pmPowerMgmtSensorsTableValueAvgInt OBJECT-TYPE
       SYNTAX             Integer32
       MAX-ACCESS         read-only
       STATUS             current
       DESCRIPTION
       "Average value of the sensor.
        Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 28 }

pmPowerMgmtSensorsTableValueReset OBJECT-TYPE
        SYNTAX INTEGER {
                noAction(1),
                reset(2)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "noAction(1) = always returned in a GET. Does nothing if SET.
         reset(2)  = when SET the reset command is sent to sensor."
::= { pmPowerMgmtSensorsTableEntry 30 }

pmPowerMgmtSensorsTableHighCritical OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "sensor high critical (alarm) threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
         Set fails if value is lower that CurrentHighWarning.
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 40 }

pmPowerMgmtSensorsTableHighWarning OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "sensor high warning threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
         Set fails if value is higher than HighCritical or lower than LowWarning.
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 41 }

pmPowerMgmtSensorsTableLowWarning OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "sensor low warning threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
         Set fails if value is higher than HighWarning or lower than LowCritical.
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 42 }

pmPowerMgmtSensorsTableLowCritical OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "sensor low critical threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
         Set fails if value is higher than LowWarning.
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 43 }

pmPowerMgmtSensorsTableUnit OBJECT-TYPE
         SYNTAX  INTEGER {
            undefined (1),
            fahrenheit (2),
            celsius (3),
            percent (4),
            afu (5)
        }
        MAX-ACCESS         read-write
        STATUS             current
        DESCRIPTION
        "sensor unit.
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 45 }

pmPowerMgmtSensorsTableHighCriticalC OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "sensor high critical (alarm) threshold (Celcius x 10).
         to SET: use pmPowerMgmtSensorsTableHighCritical in proper units (pmPowerMgmtSensorsTableUnit).
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 50 }

pmPowerMgmtSensorsTableHighWarningC OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "sensor high warning threshold (Celcius x 10).
         to SET: use pmPowerMgmtSensorsTableHighWarning in proper units (pmPowerMgmtSensorsTableUnit).
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 51 }

pmPowerMgmtSensorsTableLowWarningC OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "sensor low warning threshold (Celcius x 10).
         to SET: use pmPowerMgmtSensorsTableLowWarning in proper units (pmPowerMgmtSensorsTableUnit).
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 52 }

pmPowerMgmtSensorsTableLowCriticalC OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "sensor low critical threshold (Celcius x 10).
         to SET: use pmPowerMgmtSensorsTableLowCritical in proper units (pmPowerMgmtSensorsTableUnit).
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 53 }

pmPowerMgmtSensorsTableHighCriticalF OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "sensor high critical (alarm) threshold (Fahrenheit x 10).
         to SET: use pmPowerMgmtSensorsTableHighCritical in proper units (pmPowerMgmtSensorsTableUnit).
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 60 }

pmPowerMgmtSensorsTableHighWarningF OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "sensor high warning threshold (Fahrenheit x 10).
         to SET: use pmPowerMgmtSensorsTableHighWarning in proper units (pmPowerMgmtSensorsTableUnit).
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 61 }

pmPowerMgmtSensorsTableLowWarningF OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "sensor low warning threshold (Fahrenheit x 10).
         to SET: use pmPowerMgmtSensorsTableLowWarning in proper units (pmPowerMgmtSensorsTableUnit).
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 62 }

pmPowerMgmtSensorsTableLowCriticalF OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
        "sensor low critical threshold (Fahrenheit x 10).
         to SET: use pmPowerMgmtSensorsTableLowCritical in proper units (pmPowerMgmtSensorsTableUnit).
         Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 63 }

END